EasyManua.ls Logo

Keba ServoOne - Page 347

Keba ServoOne
493 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
11.6.3.8Error2-8(emergencycode6320h)
Cause: Errorinpowerstage initialization; selected devicevoltagenot supported
Suggested steps:
Choose different voltage level and/ or switching frequency
Thisissueisprobably
causedbyanunsuitable
parametersetting.
l Saveyourparametersetforalaterrestore.
l See'historyofparameterchanges'andundo
thelatestchanges.
l Pleasecheckyourparametersetfor
implausiblesettings.
l Pleasesetdevicetofactorysetting,restart,and
seeiftheerroroccursagain.
l Whenreportingthiserrortoyourservice
partner,pleaseincludeyourdevice's
parametersetting.
Thisisprobablyasoftware
issue.
l Pleasetrytoswitchtoadifferentversionof
devicefirmware.
l Saveyourdatasetandresettheaxismoduleto
factorysetting.Seeiftheerrorpersists,orifit
comeswithactivatingacertainfeature.
ID No.: 0842.26B.5-01Date: 09.2020
ServoOne- Device Help
347
11 Alarms & warnings
11.6.3.9Error2-9(emergencycode6320h)
Cause: Overvoltagein DC link
Suggested steps:
Please check parameter (749).
Anover-voltageoccurred. l Pleasecheckiftheactualgridvoltagematches
thesupplysetting(parameterPST_
VoltageSupply)
l Over-voltagemaybecausedbyadecelerating
axis,possiblywithhighinertia.Reduce
decelerationramp.
l Considerusingabrakingresistorwithhigher
power.Ifthesupplyunithasaninternal
brakingresistor,pleasecontactyourservice
partner.