11.6.3.6Error2-6(emergencycode6320h)
Cause: Parameter ID is multiply defined
Suggested steps:
Switch off/on device. Please contact your service provider if this error occurs again
Thisisprobablyasoftware
issue.
l Pleasetrytoswitchtoadifferentversionof
devicefirmware.
l Saveyourdatasetandresettheaxismoduleto
factorysetting.Seeiftheerrorpersists,orifit
comeswithactivatingacertainfeature.
ID No.: 0842.26B.5-01Date: 09.2020
ServoOne- Device Help
346
11 Alarms & warnings
11.6.3.7Error2-7(emergencycode5400h)
Cause: Theselected switchingfrequencyis notsupported
Suggested steps:
Choose different voltage level and/ or switching frequency
Thisissueisprobably
causedbyanunsuitable
parametersetting.
l Saveyourparametersetforalaterrestore.
l See'historyofparameterchanges'andundo
thelatestchanges.
l Pleasecheckyourparametersetfor
implausiblesettings.
l Pleasesetdevicetofactorysetting,restart,and
seeiftheerroroccursagain.
l Whenreportingthiserrortoyourservice
partner,pleaseincludeyourdevice's
parametersetting.
Thisisprobablyasoftware
issue.
l Pleasetrytoswitchtoadifferentversionof
devicefirmware.
l Saveyourdatasetandresettheaxismoduleto
factorysetting.Seeiftheerrorpersists,orifit
comeswithactivatingacertainfeature.