11.6.3.3Error2-3(emergencycode5530h)
Cause: Error in parameter saving routine
Suggested steps:
Switch off/on device. Please contact your service provider if this error occurs again
Thisissueisprobably
causedbyanunsuitable
parametersetting.
l Saveyourparametersetforalaterrestore.
l See'historyofparameterchanges'andundo
thelatestchanges.
l Pleasecheckyourparametersetfor
implausiblesettings.
l Pleasesetdevicetofactorysetting,restart,and
seeiftheerroroccursagain.
l Whenreportingthiserrortoyourservice
partner,pleaseincludeyourdevice's
parametersetting.
Anunexpectederrorinthe
filesystemhasoccurred.
l Pleasereportthiserrortoyourservicepartner.
l Pleasecheckwithyourservicepartnerhowto
generateanimagefileofthedrive.
l PleaseprovidetheDriveManagermessage
log.
Thisisprobablyasoftware
issue.
l Pleasetrytoswitchtoadifferentversionof
devicefirmware.
l Saveyourdatasetandresettheaxismoduleto
factorysetting.Seeiftheerrorpersists,orifit
comeswithactivatingacertainfeature.
ID No.: 0842.26B.5-01Date: 09.2020
ServoOne- Device Help
345
11 Alarms & warnings
11.6.3.4Error2-4(emergencycode6320h)
Cause: Error in paralist while adding a new parameter
Suggested steps:
Switch off/on device. Please contact your service provider if this error occurs again
Thisisprobablyasoftware
issue.
l Pleasetrytoswitchtoadifferentversionof
devicefirmware.
l Saveyourdatasetandresettheaxismoduleto
factorysetting.Seeiftheerrorpersists,orifit
comeswithactivatingacertainfeature.
11.6.3.5Error2-5(emergencycode5530h)
Cause: Parameter check failed
Suggested steps:
Switch off/on device. Please contact your service provider if this error occurs again
Thisisprobablyasoftware
issue.
l Pleasetrytoswitchtoadifferentversionof
devicefirmware.
l Saveyourdatasetandresettheaxismoduleto
factorysetting.Seeiftheerrorpersists,orifit
comeswithactivatingacertainfeature.