11.6.6.3Error5-3(emergencycode2350h)
Cause: Measuringrangeof ADconverterexceeded
Suggested steps:
Please check power wiring and control settings
Anovercurrentwas
detected.
l Pleasecheckcurrentcontrolsettingsandstep
response.
l Checkthemotor'ssaturationsettings
(parameterMOT_LSigDiff).Iftheerror
occurredinhigh-currentrange,lower
saturationvaluesmanually.
l Ifpossible,reducetheneededcurrent,
especiallyinlow-frequencyrange.
l Ifpossible,lowertheswitchingfrequencyor
enableautomaticfrequencyselection.
l Checkiftheencoderoffsetissetproperly.
l Considerusinganaxismodulewithhigher
currentrating.
Thisispossiblyahardware
issue
Ifothermeasuresfailtosolvetheproblem,please
replacetheservocontroller.
ThisispossiblyanEMC
issue.Thisisverylikelyifthe
problemoccurswhen
switchingonmotorcontrol
and/orwhenconnectingDC
linkpowersupply.
l Pleasecheckthedevicecablingforproper
connection.
l Pleasecheckdevicegrounding,i.e.the
connectiontoametalbackplaneandcabinet
connectiontoearth.
l Checkmotorgroundingandmotorcable
length.
ID No.: 0842.26B.5-01Date: 09.2020
ServoOne- Device Help
350
11 Alarms & warnings
11.6.6.4Error5-4(emergencycode2250h)
Cause: Short-circuittestoninitialization
Suggested steps:
Please check power wiring for short-circuit
Anovercurrentwas
detected.
l Pleasecheckcurrentcontrolsettingsandstep
response.
l Checkthemotor'ssaturationsettings
(parameterMOT_LSigDiff).Iftheerror
occurredinhigh-currentrange,lower
saturationvaluesmanually.
l Ifpossible,reducetheneededcurrent,
especiallyinlow-frequencyrange.
l Ifpossible,lowertheswitchingfrequencyor
enableautomaticfrequencyselection.
l Checkiftheencoderoffsetissetproperly.
l Considerusinganaxismodulewithhigher
currentrating.
Thisispossiblyahardware
issue
Ifothermeasuresfailtosolvetheproblem,please
replacetheservocontroller.
ThisispossiblyanEMC
issue.Thisisverylikelyifthe
problemoccurswhen
switchingonmotorcontrol
and/orwhenconnectingDC
linkpowersupply.
l Pleasecheckthedevicecablingforproper
connection.
l Pleasecheckdevicegrounding,i.e.the
connectiontoametalbackplaneandcabinet
connectiontoearth.
l Checkmotorgroundingandmotorcable
length.

Table of Contents