EasyManua.ls Logo

Keba ServoOne - Page 354

Keba ServoOne
493 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
11.6.7.4Error6-4(emergencycode4310h)
Cause: PTC/TSS error, resistance still higher than 1650 Ohm after overtemperature
Suggested steps:
Wait and let motor cool down. Reduce motor load or change motion cycle.
Themotortemperatureistoo
high.
l Pleaseletthemotorcooldown
l Pleasecheckmotortemperatureandmotor
temperatureresistance(PTCsensorsdonot
reportthemotortemperature).Ifthevaluesare
notplausible,checkcablesandsensortype.
l Ifyouarenotusingasystemmotor,please
checkwiththemotormanufacturerifthemotor
canstandahighertemperature
ID No.: 0842.26B.5-01Date: 09.2020
ServoOne- Device Help
354
11 Alarms & warnings
11.6.7.5Error6-5(emergencycode4310h)
Cause: Motor protection method not supported
Suggested steps:
Try to use different sensor connection, or contact your service provider
Thisissueisprobably
causedbyanunsuitable
parametersetting.
l Saveyourparametersetforalaterrestore.
l See'historyofparameterchanges'andundo
thelatestchanges.
l Pleasecheckyourparametersetfor
implausiblesettings.
l Pleasesetdevicetofactorysetting,restart,and
seeiftheerroroccursagain.
l Whenreportingthiserrortoyourservice
partner,pleaseincludeyourdevice's
parametersetting.

Table of Contents

Related product manuals