11.6.7.4Error6-4(emergencycode4310h)
Cause: PTC/TSS error, resistance still higher than 1650 Ohm after overtemperature
Suggested steps:
Wait and let motor cool down. Reduce motor load or change motion cycle.
Themotortemperatureistoo
high.
l Pleaseletthemotorcooldown
l Pleasecheckmotortemperatureandmotor
temperatureresistance(PTCsensorsdonot
reportthemotortemperature).Ifthevaluesare
notplausible,checkcablesandsensortype.
l Ifyouarenotusingasystemmotor,please
checkwiththemotormanufacturerifthemotor
canstandahighertemperature
ID No.: 0842.26B.5-01Date: 09.2020
ServoOne- Device Help
354
11 Alarms & warnings
11.6.7.5Error6-5(emergencycode4310h)
Cause: Motor protection method not supported
Suggested steps:
Try to use different sensor connection, or contact your service provider
Thisissueisprobably
causedbyanunsuitable
parametersetting.
l Saveyourparametersetforalaterrestore.
l See'historyofparameterchanges'andundo
thelatestchanges.
l Pleasecheckyourparametersetfor
implausiblesettings.
l Pleasesetdevicetofactorysetting,restart,and
seeiftheerroroccursagain.
l Whenreportingthiserrortoyourservice
partner,pleaseincludeyourdevice's
parametersetting.