11.6.37.4Error39-3(emergencycode2350h)
Cause: Maximum phase difference detected
Suggested steps:
Thecontrolsystemfailedto
trackthereferencevalue
l Pleasecheckiftheaxisisblocked.
l Trytoreduceaccelerationordeceleration.
l Ifreferencespeedishigherthanthemotor
ratedspeed,pleasecheckfieldweakening
settings.Infield-weakeningrange,the
availabletorquepercurrentisreduced.
Thisissueisprobably
causedbyanunsuitable
parametersetting.
l Saveyourparametersetforalaterrestore.
l See'historyofparameterchanges'andundo
thelatestchanges.
l Pleasecheckyourparametersetfor
implausiblesettings.
l Pleasesetdevicetofactorysetting,restart,and
seeiftheerroroccursagain.
l Whenreportingthiserrortoyourservice
partner,pleaseincludeyourdevice's
parametersetting.
ID No.: 0842.26B.5-01Date: 09.2020
ServoOne- Device Help
429
11 Alarms & warnings
11.6.37.5Error39-4(emergencycode2350h)
Cause: TWIN-Monitoring: position difference between master and slave is too large
Suggested steps:
Thecontrolsystemfailedto
trackthereferencevalue
l Pleasecheckiftheaxisisblocked.
l Trytoreduceaccelerationordeceleration.
l Ifreferencespeedishigherthanthemotor
ratedspeed,pleasecheckfieldweakening
settings.Infield-weakeningrange,the
availabletorquepercurrentisreduced.
Thisissueisprobably
causedbyanunsuitable
parametersetting.
l Saveyourparametersetforalaterrestore.
l See'historyofparameterchanges'andundo
thelatestchanges.
l Pleasecheckyourparametersetfor
implausiblesettings.
l Pleasesetdevicetofactorysetting,restart,and
seeiftheerroroccursagain.
l Whenreportingthiserrortoyourservice
partner,pleaseincludeyourdevice's
parametersetting.
11.6.37.6Error39-5(emergencycode2350h)
Cause: TWIN-Monitoring: Power fail on remote device
Suggested steps:
-