EasyManua.ls Logo

Keba ServoOne - Page 482

Keba ServoOne
493 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
17.2.2Loadingtheparameterdatasetfromthefilesys-
tem
No. Action
1
Load the parameter set from the PC to the file system of the drive
controller via FTP script:
open 192.168.39.5
Servo
Drive
mkdir /para
cd /para
put PDS00.dmd
quit
Theparameterdatasetisnowpresentinthedrivecontrollerfilesystem.
2
Enter the name of the parameter data set to be read
Withbyte0ofP 2010[0] - COM_CFG_ID:Specifiesthenameofthedata
settoberead.
0-99meansPDS00...PDS99.
3
Specify options:
Withbyte1ofP 2010[0] - COM_CFG_ID:
Specificationoftheoptions.
Bit0=1:Savethedatasetpermanentlytothenon-volatileaxiscontroller.
4
Readtheparameterdatafromthefilesystemandwritetothedevice
parameters.
P 2009[0] - COM_CFG_File=19.
5
Ifeverythinghasworkedproperly,P 2009[0] - COM_CFG_Fileis
automaticallysetto0=Readyonceagain.
Ifthereisanerror,P 2009[0] - COM_CFG_Fileissetto-2=error.
ID No.: 0842.26B.5-01Date: 09.2020
ServoOne- Device Help
482
17 Enhanced/additional functions

Table of Contents

Related product manuals