8 SENSe Subsystem
194 U8480 Series Programming Guide
[SENSe[1]:]CORRection:DCYCle|GAIN3[:INPut][:MAGNitude]
<numeric_value>
This command is used to set the duty cycle for the pulse power measurement.
Pulse power measurements average out any aberrations in the pulse such as
overshoot or ringing. The result returned for a pulse power measurement is a
mathematical representation of the pulse power rather than an actual
measurement.
The U8480 Series measures the average power in the pulsed input signal and then
divides the result by the duty cycle value to obtain a pulse power reading.
Entering a value using this command automatically turns the
[SENSe[1]:]CORRection:DCYCle|GAIN3:STATe command to ON.