EasyManua.ls Logo

Korg Oasys - Loading Individual Banks from a.PCG File; Loading Data by Individual Item or Bank

Korg Oasys
245 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Loading data from disk Loading individual banks from a .PCG file
179
Loading individual banks from a .PCG file
1. Selectthe.PCGfilecontainingthedatayouwant
toload,andchoosethepagemenucommand
“LoadSelected.”
Refertosteps1–4of“Loading.PCG,.SNG,and.KSC
files”onpage 177.”Selectthe.PCGfileinstep5.
2. Pressthepagemenubuttontoopenthepage
menu,andchoose“Load
Selected.”
Youcanloadindividualbanksbyusing“.PCG
Contents”inthedialogboxtoselecttheloadsource
bank,and“To”toselecttheloaddestinationbank.
Whenyouexecuteloading,onlytheprograms,
combinations,drumkits,andwavesequencedataof
theselectedbankwillbeloadedintothe
load
destinationbankyouspecify.Globalsettingdatawill
notbeloaded.
Ifyouset“.PCGContents”toBankINTA,and“To”to
BankINTA,datawillbeloadedasfollows.
Programs
BankINTA:loadedintoBankINTA
Combinations
BankINTA:loadedintoBankINTA
Drum
Kits
INT:loadedintoBankINT
WaveSequences
INT:loadedintoBankINT
Whendataisloadedintoabankthatisdifferentthan
itsoriginalbank,thedata(bank,program,pattern,and
kitnumbers,etc.)willautomaticallybereconfiguredso
thatafterloading,thevarioustypesofdatawill
correspondcorrectlyineachmode.
Thefollowingdatawillalsobereconfigured
automaticallyifyouhavechecked“Load.SNGtoo”(so
thatsongdataisloadedatthesametime),the
followingdatawillalsobereconfiguredautomatically
inordertoensurethatthesongdataplaysback
correctly.
•Thebank
ofeachprogramusedbycombinations
•Thebankofeachdrumkitandwavesequenceused
byeachprogram
•Thebankoftheprogramusedbyeachtrackofthe
song
•Ifthesongcontainstrack/patternevents,the
programbankswithintheseevents
Loading data by individual item or bank
TheOASYSletsyouloadprograms,combinations,
drumkits,andwavesequencesindividuallyorby
individualbanks.
Thisisaconvenientwaytorearrangecombinationsin
theorderinwhichyouwillusethemduringalive
performance.
Beawarethatifyouchangetheorderofprograms,
thesoundsplayed
bycombinationsmayalsobe
affected.
Asanexamplehere,wewillexplainhowa
combinationsavedinbankINTDcanbeloadedinto
INTE000.
1. Movetothe“BankINTD”directory,andselect
thecombinationthatyouwanttoload.(.PCG
file/Combinations/BankINTD/)
Theprocedureisasfollows.
1)
Performsteps1–5under“Loading.PCG,.SNG,
and.KSCfiles”onpage 177.Selectthe.PCGfile
containingthedatayouwanttoload(itwillbe
highlighted),andpresstheOpenbutton.
2)Press“Combinations”tohighlightit,andpress
theOpenbutton.
3)Press“BankD”tohighlightit,andpressthe
Openbutton.
4)Pressthescrollbartofindthecombinationyou
wanttoload,andhighlightitinthedisplay.

Table of Contents

Related product manuals