EasyManua.ls Logo

Kyocera TASKalfa 8002i - Page 1349

Kyocera TASKalfa 8002i
1627 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
2WA/2NJ/2RK
7-489
F18X Abnormality detecting in a Video control sec-
tion
(1) Check the connection state of the harness and the connector
between Engine<=>Main PWB, and perform an operation check.
(2) Initialize HDD and perform an operation check.
(FULL of U024) *
(3) U021 Controller backup initialization is carried out and an oper-
ation check is performed.
(4) Exchange Engine PWB, and perform an operation check.
(5) Exchange Main PWB, and perform an operation check.
(6) Get USBLOG and contact to service headquarters.
* : Only HDD standard model
(Main<=>Engine)
Main PWB: YC65
Engine PWB: YC3
F1DX Abnormality detecting of the image memory
Management Department
(1) Initialize HDD and perform an operation check.
(FULL of U024) *
(2) U021 Main backup initialization is carried out and an operation
check is performed.
(3) Exchange Main PWB, and perform an operation check.
(4) Exchange HDD, and perform an operation check. *
(5) Get USBLOG and contact to service headquarters.
* : Only HDD standard model
* F1D4: Poor arrangement of Random
Access Memory
(1) Confirmation of U340
(2) Initialization of a set point (U021)
F21X,
F22X,
F23X
Abnormality detecting in an image-processing
part
(1) Initialize HDD and perform an operation check.
(FULL of U024) *
(2) U021 Main backup initialization is carried out and an operation
check is performed.
(3) Exchange Main PWB, and perform an operation check.
(4) Exchange HDD, and perform an operation check. *
(5) Get USBLOG and contact to service headquarters.
* : Only HDD standard model
F24X Abnormality detecting in the system Manage-
ment Department
(1) Initialize HDD and perform an operation check.
(FULL of U024) *
(2) U021 Main backup initialization is carried out and an operation
check is performed.
(3) Exchange Main PWB, and perform an operation check.
(4) Exchange HDD, and perform an operation check. *
(5) Get USBLOG and contact to service headquarters.
* : Only HDD standard model
* F248 is the abnormalities of a printer
process.
In recurring by specific printer data,
please give me cooperation at acquisi-
tion of capture data and USBLOG.
(In case of controller abnormality)
How to reset is only power switch
Off/On.
USBLOG is required in the investi-
gation.
F25X Abnormality detecting in a network manage-
ment department
(1) Initialize HDD and perform an operation check.
(FULL of U024) *
(2) U021 Main backup initialization is carried out and an operation
check is performed.
(3) Exchange Main PWB, and perform an operation check.
(4) Get USBLOG and packet capture, and contact to service head-
quarters.
* : Only HDD standard model
* It may occur according to a visitor's
network environment.
F26X,
F27X,
F28X,
F29X,
F2AX
Abnormality detecting in the system Manage-
ment Department
(1) Initialize HDD and perform an operation check.
(FULL of U024) *
(2) U021 Main backup initialization is carried out and an operation
check is performed.
(3) Exchange Main PWB, and perform an operation check.
(4) Exchange HDD, and perform an operation check. *
(5) Get USBLOG and contact to service headquarters.
* : Only HDD standard model
(SSM: F26X)
Num-
ber
Contents Verification procedure / check point Remarks

Table of Contents