EasyManua.ls Logo

Kyocera TASKalfa 8002i - Page 172

Kyocera TASKalfa 8002i
1627 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
2NJ/2RK
2-123
12. Connect the connector (b) of the heater outlet set (a) to the paper feeder side connector (c).
13. Attach the heater outlet set (a) with two screws (d)(M3×8).
Figure 2-232
14. Connect the side feeder (a) to the main unit side paper feeder (b) with the AC cord (c) and the connector wire (d).
Figure 2-233
15. Reattach the parts in the original position.
16. Turn the power on and set to [mode1/mode2] In maintenance mode U327 [Cassette heater control setting].
IMPORTANT
When connecting the cassette heater, do not unplug the power cord. (Power is supplied when the power is switched off)
a
b
c
d
d
b
a
c
d