2WA/2NJ/2RK
4-178
6. Disconnect the connector (a) from the
main PWB connector (c).
7. Remove the PWB unit (d).
IMPORTANT
When disconnect the connector (a) from the
connector of main PWB (b), straightly pull out
against the main PWB (b) and do not pull out
on the skew.
When pulling out on the skew, it causes the
damage of FPC (f).
Figure 4-262
d
c
d
b
a
14j0411