2WA/2NJ/2RK-1
6-54
Contents
Adjust the magnification in the main and sub scanning direction of the table scanning.
Purpose
Adjusts the magnification in the main and sub scanning direction of the table scanning if the
above incorrect
Precautions
The magnification adjustment in the main scanning direction could cause black streaks depend-
ing on the content of the original document.
Adjust the magnification of the scanner in the following order.
U065(main scanning direction)(P.6-54) > U065((sub scanning direction)(P.6-54)
Method
1.Press the [Start] key.
2.Press the [System Menu] key.
3.Place an original and press the [Start] key to make a test copy.
4.Press the [System Menu] key.
5.Select the item to adjust.
*: Initial setting value is a reference value as the value changes by the adjustment at the production.
Adjustment: Main Scan
1.By using the [+] [-] keys or the numeric keys, change the setting value.
For the copy example 1, increase the value.
For the copy example 2, decrease the value.
* :When the setting value is increased, the image widens, and it narrows when the setting
value is decreased.
Figure 6-7
2.Press the [Start] key to set the setting value.
U065 Adjusting the magnification for table scanning
(Message: Adjust Scanner Motor Speed)
Items Contents Setting range Data
variation
Initial
setting
Main Scan Scanner magnification in the main scan-
ning direction
-75 to 75 0.02%
Sub Scan Adjusts scanner magnification in the sub-
scanning direction
-125 to 125 0.02% 0
Original Copy
example 1
Copy
example 2