2WA/2NJ/2RK-2
6-80
Setting: OHP
1.Select the item to set.
2.Change the setting value by using [+] [-] key or the numeric keypad.
3.Press the [Start] key to set the setting value.
Setting: Bias
1.Select the item to set.
2.Change the setting value by using [+] [-] key or the numeric keypad.
3.Press the [Start] key and then fix the setting value.
Completion
Press the [Stop] key.
* :The screen for selecting a maintenance item No. is displayed.
Items Contents Setting range Data
varia-
tion
Initial setting
90
ppm
80
ppm
70
ppm
Width=105 Setting that paper width is equal to 105 0 to 255 1 97 97 94
Width=210 Setting that paper width is equal to 210 0 to 255 1 97 97 94
Width=297 Setting that paper width is equal to 297 0 to 255 1 89 89 87
Items Contents Setting range Data
varia-
tion
Initial setting
90
ppm
80
ppm
70
ppm
Reverse Reverse bias setting (Full speed) 0 to 255 1 160 160 160
Reverse Half Reverse bias setting (Half speed) 0 to 255 1 160 160 160
Cleaning Cleaning (Full speed) 0 to 255 1 106 104 100
Cleaning
Half
Cleaning (Half speed) 0 to 255 1 91 91 89