2WA/2NJ/2RK
6-85
Contents
Adjust On/Off timing of the transfer high voltage output.
Purpose
Prevent paper from being rolled up by the drum.
Setting
1.Press the [Start] key.
2.Select the item to set.
3.Change the setting value by using [+] [-] key or the numeric keypad.
* :If the numeric value is increased, the transfer ON timing delays and paper separation
becomes good.paper separation failure occurs.
(The front end of transfer margin at a paper output becomes wide.)
If the numeric value is decreased, the transfer ON timing is advanced and paper separation
becomes bad.
(The back end of transfer margin at a paper output becomes wide.)
4.Press the [Start] key to set the setting value.
Completion
Press the [Stop] key.
* :The screen for selecting a maintenance item No. is displayed.
U128 Transfer timing adjustment
(Message: Adjust Transfer Timing)
Items Contents Setting range Data
variation
Initial
setting
On Timing
1st
Surface transfer On timing adjustment
value
-200 to 200 0.1m sec 10
Off Timing Transfer Off timing adjustment value -200 to 200 0.1m sec -18