2WA/2NJ/2RK
6-176
Error codes
Codes Contents Corrective action
00 Automatic adjustment success -
01 Black band detection error
(Table scanning leading edge skew in the
sub-scanning direction)
1. Set the original correctly and
execute the adjustment again.
2. Check lighting of the lamp or
replace it.
04 Black band is not detected (Table leading
edge in the sub-scanning direction)
05 Black band is not detected (Table far end in
the main scanning direction)
06 Black band is not detected (Table near end
in the main scanning direction)
07 Black band is not detected (Table trailing
edge in the sub-scanning direction)
08 Black band is not detected (DP far end in
the main scanning direction)
1. Check the attachment position of
DP.
2. Check lighting of the lamp or
replace it.
3. Check the back and front of the
adjustment original.
09 Black band is not detected (DP near end in
the main scanning direction)
0a Black band is not detected (DP leading
edge in the sub-scanning direction)
0b Black band is not detected
(Original check of DP leading edge in the
sub-scanning direction)
0c Black band is not detected (DP trailing
edge in the sub-scanning direction)
0d White band is not detected (DP trailing
edge in the sub-scanning direction)
0e DMA time out Turn the power switch off then on,
and execute again.
0f Magnification error in the sub-scanning
direction
1. Turn the power switch off then
on, and execute again.
2. Adjust manually.
(U065 to U067, U070 to U072)
10 Leading edge error in the sub-scanning
direction
11 Trailing edge error in the sub-scanning
direction
12 DP skew error in the sub-scanning direc-
tion
13 Maintenance request error Turn the power switch off then on,
and execute again.
14 Center line error in the main scanning
direction
1. Turn the power off and on, and
execute again.
2. Adjust manually.
(U065 to U067, U070 to U072)
15 DP skew error in the main scanning direc-
tion
16 Magnification error in the main scanning
direction