2WA/2NJ/2RK
6-186
Setting: DP(ChartB)
* :This setting is usually unnecessary.
*1: Centimeter specification, 0*2: inch specification
1.Measure the distance "A" from the leading edge to the black belt (inside) on the adjustment
original.
2.Enter the value solved in "Lead" using the the [+] [-] keys keys.
3.Measure the distance "B" from the left edge to the black belt (inside) on the adjustment original.
4.Enter the values measured in "Main Scan" using the the [+] [-] keys keys.
5.Measure the distance "C" from the leading black belt (inside) to the trailing black belt (inside)
on the adjustment original.
6.Enter the values measured in "Sub Scan" using the the [+] [-] keys keys.
7.Press the [Start] key to set the setting value.
Figure 6-26
Completion
Press the [Stop] key.
* :The screen for selecting a maintenance item No. is displayed.
Items Contents Setting range Data
variation
Initial
setting
Lead Set the adjustment value of the
leading edge.
14.0 to 16.0
0.56 to 0.63
0.1mm
0.01 inch
15.0
0.6
Main Scan Sets the adjustment value of the
left edge.
14.0 to 16.0
0.56 to 0.63
0.1mm
0.01 inch
15.0
0.6
Sub Scan Set the adjustment value of the
trailing edge.
388.0 to 392.0
15.28 to 15.43
0.1mm
0.01 inch
390.0
15.36
Lead
Main Scan
Sub Scan
Original for adjustment Chart 2-2 (P/N: 302AC68243)