Correct the side multi tray and the multi feed sensor threshold of the document professor.
Purpose
When the multi feed frequently occurs, set the threshold in accordance to the environment.
Execution
1.Press the [Start] key.
2.Select the item to set.
* :The screen for setting is displayed.
Execution
1.Select the item to set.
Setting: On/Off Config
1.By using [+] [-] or the numeric keys, change the setting value.
* :Initial setting: On(1)
2.Press the [Start] key and then fix the setting value.
Setting: Conveying Sensor
1.Select the item to set.
* : The sensor value is for display only when using the DP.
U460 Conveying sensor adjustment
(Message: Adjust Conveying Sensor)
Display Contents
DP Adjust/set the DP conveying sensor.
SMT Adjust/set the SMT conveying sensor.
Display Contents
Conveying Sensor Setting the multi feed sensor/Executing the calibration
On/Off Config Setting the multi feed sensor switch ON/OFF
Display Description
On Valid for the multi feed detection.(1)
Off Invalid for the multi feed detection.(0)
Display Description
Threshold(Single) Paper conveying threshold setting
Threshold(Multi) Multi feed threshold setting
Execute Executing the calibration
Sensor(Non-P)* Display the sensor value when there is no paper.
Sensor* Display the sensor value when there is paper.