Refer s to the ID correction data.
Purpose
Execute for data check.
Method
1.Press the [Start] key.
2.Select the item to set.
* :The screen is switched.
Refer ence: TCONT
1.Select [TCONT].
* :The current value is displayed.
Reference: Laser Power
* :The current value is displayed.
Reference: Laser Power(En)
* :The current value is displayed.
U465 ID correction data
(Message: ID Adjustment Data)
Items Contents
TCONT Developer bias control value after ID correction
Laser Power
Display the light intensity control value.
Laser Power(En)
Display the exposure level (En)
Laser Power(Drum)
Display the half exposure level of the drum (Drum)
Laser Power(Max)
Display the maximum exposure level (Max)
Bias Calib Sensor value for the toner layer calibration
T7 CTD T7 control value
Stress Primary transfer belt durability
Display Contents
Before(K) Black developer bias control value before ID correction
After(K) Black developer bias control value after ID correction
Items Contents
K Displays the Black light intensity control value.
Items Contents
K Displays the Black light intensity control value.