Explains fault indication, history access, and fault handling actions like reset and mute.
Provides electrical safety warnings and general requirements for installation.
Emphasizes the importance of earthing all electrical equipment for safety.
Explains the three-phase current inputs and CT connection requirements.
Describes the three analog outputs for 4-20mA signal transmission.
Provides troubleshooting steps for modem communication issues, focusing on LED status.
Guides on configuring a cellular modem for PumpView via serial connection.
Guides on selecting the Ethernet modem and configuring DNP slave for PumpView.
Details entering UDP connection type, IP address, subnet mask, and gateway.
Outlines the steps to complete the Setup Wizard for initial product configuration.
Details the configuration steps for a pump station setup.
Outlines the configuration steps for a reservoir setup.
Details the configuration steps for an RTU setup.
Explains post-wizard configuration like Flow, Motor Protection, and VFD settings.
Lists crucial parameters that should be set correctly during the initial Setup Wizard.
Details the final configuration summary and controller restart process.
Guides on unassigning unused pump faults to simplify configuration.
Explains the need for unit restart after fault configuration changes and options.
Explains simulating levels to test control panels before installation.
Disables SCADA controls for isolation during maintenance.
Describes configuring duration and options for maintenance mode.
Provides a high-level overview of the MultiSmart's features and functionalities.
Explains the Pump Station Manager module's logic and operator interface.
Details the Reservoir Monitor configuration and its capabilities.
Describes pump modes, setpoints, alarms, delays, I/O, faults, and level devices.
Details profiles, station optimization functions, and watchdog.
Describes modules for energy monitoring, supply protection, data logging, and flow.
Explains fault handling, security features, PLC extension, and logic engine.
Covers accessing security screens, managing users, and changing administrator passwords.
Details using security keys for access and managing key-based user accounts.
Explains default setpoints and four independent level alarms.
Guides on setting pump activation and deactivation levels via the interface.
Details setting points for four independent level alarms.
Guides on enabling or disabling specific level alarms.
Explains setting activation/deactivation and inter-pump delays.
Lists eight schemes for sequencing pumps within a group.
Guides on changing pump alternation schemes and fixed duty settings.
Explains favoring the most efficient pump for energy savings.
Guides on moving pumps between groups or reordering them.
Explains adding or removing groups and changing group alternation settings.
Details how to prevent pumps from running and display a 'Decommissioned' notice.
Details configuring various devices connected to DINs with special functions.
Lists predefined faults that can be linked to digital inputs.
Guides on selecting a fault and assigning it to a digital input, including invert options.
Guides on unassigning faults from digital inputs.
Details how to configure digital inputs via the General screen.
Explains advanced options like delay, mode, and sensitivity for digital inputs.
Guides on zeroing, spanning, and changing descriptions of analog inputs.
Explains advanced parameters affecting analog input values like delay and range.
Guides on creating Modbus masters and configuring points lists for external I/O.
Details connecting ADAM/ACROMAG units via Ethernet switch or crossover cable.
Lists supported ADAM Ethernet units and their IP address configuration.
Details supported ACROMAG units and their IP address configuration.
Explains how to verify communications and view read values from I/O devices.
Guides on assigning and configuring primary and backup level devices.
Details selecting probe models and entering well depth for accurate level readings.
Explains configuring probe sensitivity and assigning digital inputs.
Details configuring the MultiSmart for systems with less than 10 level sensors.
Explains the DuoProbe sensor's features and hardware/firmware requirements.
Provides recommendations for optimal DuoProbe positioning.
Guides on configuring DuoProbe settings like units, depth, and length.
Explains different faults associated with DuoProbe operation.
Guides on zeroing, spanning, and changing descriptions of analog sensors.
Recommends comparing two analog devices for fault detection.
Explains the Level Locked alarm and its configuration.
Guides on selecting fault types and configuring basic fault options.
Details advanced parameters for faults like activation delay and manual reset.
Explains configuring fault actions like pump reversal and mute options.
Guides on configuring the Delay Fail fault for monitoring digital inputs.
Guides on configuring a low flow fault using analog output from a flow meter.
Provides examples for configuring general faults like Manual Mode and Low Fuel Warning.
Details using ResetAllFaults tag for resetting multiple faults.
Guides on configuring analog outputs for re-transmitting inputs or generating signals.
Guides on configuring digital outputs and their advanced options like inversion and delay.
Provides an example of making a digital output follow a digital input state.
Discusses programmable profiles for independent setpoints and pump control parameters.
Guides on selecting profiles via user interface, digital tag, or timer.
Guides on editing setpoints for profiles via the Switch Profile button.
Details editing profile parameters like activation set points and station optimization.
Explains configuring profiles via the Advanced menu, including DIN activation and timers.
Lists configurable parameters for optimizing pump station performance.
Details configuring pump reversal modes, durations, delays, and automatic reversal.
Describes using maximum off time to empty the station and reduce odors.
Explains preventing pumps from running too long by cycling them.
Allows pumps to run past deactivation point to completely empty the well.
Details controlling a well washer to coordinate with pumping cycles.
Explains controlling well mixers via pump cycles or time intervals.
Parameters for primary/backup level devices and failover logic.
Guides on configuring motor protection settings and copying them between pumps.
Explains entering CT ratios for accurate motor current calculation.
Details configuring faults like phase imbalance, over-current, and low power factor.
Details fault configuration settings like enabled, threshold, and delays.
Describes the 1000VDC IRT for testing motor windings and configuring thresholds.
Guides on enabling IRT and configuring warning threshold resistance.
Explains isolating the IRT voltage using isolation contactors and digital outputs.
Explains conditions that inhibit the IRT test, like high voltage or load.
Guides on manually activating the IRT and performing tests.
Explains RTU capabilities and supported communication protocols.