EasyManua.ls Logo

NEC UNIVERGE SV8500 - Page 514

NEC UNIVERGE SV8500
975 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
– 467 –
CHAPTER 3 System Messages
The following provides detailed fault information and the solution by using the combination of data (INF, FLT, and
Detailed Info). These information are provided when FNC ( ) indicates 04.
Table 3-3 Detailed Fault Information and The Troubleshooting
INF ( ) FLT ( )
Detailed Info
Description Solution
05 03 20 0E
Failed to communicate between DPMs
Reset IPELC (IPLC). If the fault
occurs again, replace the IPELC
(IPLC) with a new one.
Restart to communicate between DPMs
08
12 0C Buffer Overflow None
10
01 01 Detect NC (CPU) WDT Reset IPELC (IPLC). If the fault
occurs again, replace the IPELC
(IPLC) with a new one.
02 01 Detect PCMCONT-0 (DSP) WDT
03 01 Detect PCMCONT-1 (DSP) WDT
08 01
Detect VC0 (CPU) WDT
Reset IPELC (IPLC). If the fault
occurs again, replace the VC0 PKG
with a new one.
Recovery VC0 (CPU)
08 04 Failed to initialize VC0 (CPU) device
09 01
Detect VC1 (CPU) WDT (Sub PKG#1)
Reset IPELC (IPLC). If the fault
occurs again, replace the VC1 PKG
with a new one.
Recovery VC1 (CPU)
09 04 Failed to initialize VC1 (CPU) device
0A 01
Detect VC2 (CPU) WDT (Sub PKG#2)
Reset IPELC (IPLC). If the fault
occurs again, replace the VC2 PKG
with a new one.
Recovery VC2 (CPU)
0A 04 Failed to initialize VC2 (CPU) device
0B 01
Detect VC3 (CPU) WDT (Sub PKG#3)
Reset IPELC (IPLC). If the fault
occurs again, replace the VC3 PKG
with a new one.
Recovery VC3 (CPU)
0B 04 Failed to initialize VC3 (CPU) device
12
00 80 Failed to download programs Reset IPELC (IPLC). If the fault
occurs again, replace the IPELC
(IPLC) with a new one.
13
42 02
Memory Fault
Memory Fault Recovery
06
40
80 13 Failed to reserve OS resource Reset IPELC (IPLC). If the fault
occurs again, replace the IPELC
(IPLC) with a new one.
43
20 0E
Failed to communicate between DPMs
4A
80 16
Failed to set LAN related data
Reset IPELC (IPLC). If the fault
occurs again, replace the IPELC
(IPLC) with a new one.
3
4 5
7 8

Table of Contents

Other manuals for NEC UNIVERGE SV8500

Related product manuals