ā 468 ā
CHAPTER 3 System Messages
Table 3-3 Detailed Fault Information and The Troubleshooting (continued)
INF ( ) FLT ( )
Detailed Info
Description Solution
06
4A
80 23
Failed to negotiate with terminals
(1) When the fault occurs in all the
terminals accommodated in
IPELC (IPLC), reset the IPELC
(IPLC). If the fault occurs again,
replace the IPELC (IPLC) with a
new one.
(2) When the fault occurs in some
terminals accommodated in
IPELC (IPLC), reset the IPELC
(IPLC). If the fault occurs again,
replace the terminals with new
ones.
58
43 10 Failed to receive packets None
43 11 Failed to send packets None
07
80 02 04 Failed to initialize PCMCONT-0 device Reset IPELC (IPLC). If the fault
occurs again, replace the IPELC
(IPLC) with a new one.
90
03 04
Failed to initialize PCMCONT-1 device
08
C0
0C 04 Failed to initialize VC0 device (Sub
PKG#0)
Reset IPELC (IPLC). If the fault
occurs again, replace the VCT0 PKG
with a new one.
Complete to initialize VC0 device (Sub
PKG#0)
C1
0C 01 Detect VC0 (DSP) WDT (Sub PKG#0) None
D0
0D 04 Failed to initialize VC1 device (Sub
PKG#1)
Reset IPELC (IPLC). If the fault
occurs again, replace the VCT1 PKG
with a new one.
Complete to initialize VC1 device (Sub
PKG#1)
D1
0D 01 Detect VC1 (DSP) WDT (Sub PKG#1) None
E0
0E 04 Failed to initialize VC2 device (Sub
PKG#2)
Reset IPELC (IPLC). If the fault
occurs again, replace the VCT2 PKG
with a new one.
Complete to initialize VC2 device (Sub
PKG#2)
E1
0E 01 Detect VC2 (DSP) WDT (Sub PKG#2) None
F0
0F 04 Failed to initialize VC3 device Reset IPELC (IPLC). If the fault
occurs again, replace the VCT3 PKG
with a new one.
Complete to initialize VC3 device
F1
0F 01 Detect VC3 (DSP) WDT (Sub PKG#3) None
4 5