– 921 –
APPENDIX A
STEP 8 In PCPro Tools’ Patch menu:
1. Select the following:
• Operation: Write
• Install Data Name: Data selected in STEP 3–1
• Patch Selection: Data Name set in “Install Data Name” box of STEP 5–2
2. Press “Execute” button.
(2) Use XPAT command to apply uploaded patch files to the Telephony Server.
STEP 1 Start up XPAT command.
STEP 2 Select target Telephony Server side to apply patches using radio buttons in “Mode: ACT/ST-
BY.”
STEP 3 Press “Get” button to display “Patch Information List” (list of uploaded patch files).
• When application for all uploaded patch files have been completed:
Message “Everything has been applied.” appears.
Press “Exit” button to end XPAT command.
STEP 4 Press “Check” button to check formats for patch files.
• When all files are in correct format:
“Apply” button becomes active.
• When an incorrect file format exists:
Error message is displayed in “Check Result” column of “Patch Information List.”
“Apply” button does not become active.
STEP 5 Press “Apply” button.
Message “Do you apply patch?” appears.
Press “OK” to start applying the patch.
Note 1
• When all patch file application was successful:
Message “Patch application success. Display information is updated.” appears.
• When patch application failed:
Message “Patch application failed. Display information is updated.” appears.
Note 1: Pressing the “OK” button automatically executes readout to update the Patch Information List. When
patch application failed, the first patch file in “Applied Status” column displayed as “Unapplication”
failed to have the patch applied. Contact the patch provider when this problem occurs.
STEP 6 Press “Exit” button to end XPAT command when patch application is complete.