UANTA COMPUTER INC.
Layer 2/3/4 Managed Switch
_____________________________________________________________________________
LB9 User’s Guide 1065/1523
11.2.9.6 Configuring Time Zone Settings Page
Simple Network Time Protocol (SNTP) allows the switch to set its internal clock based on periodic
updates from a time server. Maintaining an accurate time on the switch enables the system log to record
meaningful dates and times for event entries. You can also manually set the clock using the CLI. If the
clock is not set, the switch will only record the time from the factory default set at the last bootup.
Selection Criteria
Direction
ï‚· before-utc - Sets the local time zone before (east) of UTC
ï‚· after-utc - Sets the local time zone after (west) of UTC
Configurable Data
Time Zone Name - The name of time zone, usually an acronym. (Range: 1-15 characters).
Time Zone Hours - The number of hours before/after UTC. (Range: 0-12 hours).
Time Zone Minutes - The number of minutes before/after UTC. (Range: 0-59 minutes).
ï‚· before-utc - Sets the local time zone before (east) of UTC
ï‚· after-utc - Sets the local time zone after (west) of UTC
Command Buttons
Submit - Send the updated screen to the switch. Changes take effect on the switch but these
changes will not be retained across a power cycle unless a save is performed.