UANTA COMPUTER INC.
Layer 2/3/4 Managed Switch
_____________________________________________________________________________
LB9 User’s Guide 805/1523
8.3.2 Configuration Commands
8.3.2.1 ipv6 mld query-interval
Use this command to set the MLD router’s query interval for the interface. The query-interval is the
amount of time between the general queries sent when the router is the querier on that interface. The
range for <query-interval> is 1 to 3600 seconds.
Syntax
ipv6 mld query-interval <1-3600>
no ipv6 mld query-interval
no – Use this command to reset the MLD query interval to the default value for that interface.
Default Setting
125
Command Mode
Interface Config
8.3.2.2 ipv6 mld query-max-response-time
Use this command to set the MLD querier’s maximum response time for the interface and this value is
used in assigning the maximum response time in the query messages that are sent on that interface.
The range for <query-max-responsetime> is 0 to 65535 milliseconds.
Syntax
ipv6 mld query-max-response-time <0-8387584>
no ipv6 mld query-max-response-time
no - This command resets the MLD query max response time for the interface to the default value.
Default Setting
10000 milliseconds
Command Mode
Interface Config