6.10.2 Configuration Commands
6.10.2.1 sntp broadcast client poll-interval
This command will set the poll interval for SNTP broadcast clients in seconds as a power of two where
<poll-interval> can be a value from 6 to 10.
Syntax
sntp broadcast client poll-interval <6-10>
no sntp broadcast client poll-interval
<6-10> - The range is 6 to 10.
no - This command will reset the poll interval for SNTP broadcast client back to its default value.
Default Setting
6
Command Mode
Global Config