LB9 User’s Guide 120/1523
This command sets how frequently Leave All PDUs are generated for all ports. A Leave All PDU
indicates that all registrations will be unregistered. Participants would need to rejoin in order to maintain
registration. The value applies per port and per GARP participation. The time may range from 200 to
6000 (centiseconds).
i
This command has an effect only when GVRP and GMRP are enabled.
Syntax
garp timer leaveall all < 200-6000 >
no garp timer leaveall all
<200-6000> - leave time (Range: 200 – 6000) in centiseconds.
all - All interfaces.
no - This command sets how frequently Leave All PDUs are generated for all ports to 1000
centiseconds (10 seconds).
Default Setting
1000 centiseconds (10 seconds)
Command Mode