UANTA COMPUTER INC.
Layer 2/3/4 Managed Switch
_____________________________________________________________________________
LB9 User’s Guide 187/1523
6.2.14.3 link state group
Set upstream port or downstream port for a link state group. Use ‘link state group <group id> upstream’
to set the port to be monitored.
Syntax
link state group <1-6> {downstream | upstream}
no link state group <1-6> {downstream | upstream}
no - This command disables link state group function.
Command Mode
Interface Config