6.8.3.9 dot1x re-authentication
This command enables re-authentication of the supplicant for the specified port.
Syntax
dot1x re-authentication
no dot1x re-authentication
no - This command disables re-authentication of the supplicant for the specified port.
Default Setting
Disabled
Command Mode
Interface Config
6.8.3.10 dot1x supplicant max-start
This command configure the maximum number of Start EAPOL messages to be sent in the absence of
Authenticator.
Syntax
dot1x supplicant max-start <1-10>
no dot1x supplicant max-start
Default Setting
3
Command Mode
Interface Config