UANTA COMPUTER INC.
Layer 2/3/4 Managed Switch
_____________________________________________________________________________
LB9 User’s Guide 364/1523
6.8.3.13 dot1x supplicant timeout held-period
This command configure the held period value.
Syntax
dot1x supplicant timeout held-period <seconds>
no dot1x supplicant timeout held -period
<seconds> - Range: 1-65535.
Default Setting
60
Command Mode
Interface Config
6.8.3.14 dot1x supplicant timeout start-period
This command configure the start period value.
Syntax
dot1x supplicant timeout start-period <seconds>
no dot1x supplicant timeout start-period
<seconds> - Range: 1-65535.
Default Setting
60
Command Mode
Interface Config