UANTA COMPUTER INC.
Layer 2/3/4 Managed Switch
_____________________________________________________________________________
LB9 User’s Guide 766/1523
7.7.2.3 ip irdp holdtime
This commands configures the value, in seconds, of the holdtime field of the router advertisement sent
from this interface.
Syntax
ip irdp holdtime < maxadvertinterval-9000 >
no ip irdp holdtime
< maxadvertinterval-9000 > The range is the maxadvertinterval to 9000 seconds.
no - This command configures the default value, in seconds, of the holdtime field of the router
advertisement sent from this interface.
Default Setting
The default value is 3* maxadvertinterval (600) =1800.
Command Mode
Global Config
7.7.2.4 ip irdp maxadvertinterval
This commands configures the maximum time, in seconds, allowed between sending router
advertisements from the interface.
Syntax
ip irdp maxadvertinterval < minadvertinterval-1800 >
no ip irdp maxadvertinterval
< minadvertinterval-1800 > - The range is 4 to 1800 seconds.
no - This command configures the default maximum time, in seconds.
Default Setting
The default value is 600.
Command Mode
Global Config