EasyManua.ls Logo

Ricoh A66 - Page 439

Ricoh A66
733 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
SC101: Lamp failure (broken or persistently on)
Type: 3
- Description -
When the lamp regulator detects that the exposure lamp is not turned
on or is not turned off, the scanner IPU informs the SCU of this.
- Detection Timing -
Failure to go on (break) is detected when the lamp is turned on.
Failure to go off (persistently on) is detected when the lamp is turned
off.
- Possible Causes -
Lamp regulator defective
Exposure lamp open
Optics thermoswitch open
SP-Log: 7-402-1
SC120: Scanner HP sensor abnormal - Stays off
Type: 3
- Description -
The scanner IPU board notifies the SCU when the home position
sensor does not go on even though the scanner carriage has been
returned to the home position during the scanner carriage homing
process of the power-on sequence.
- Detection Timing -
When the power switch is turned on and the scanner homing operation
starts
- Possible Causes -
Scanner HP sensor defective
SP-Log: 7-402-1
SERVICE CALL CONDITIONS
A166/A187/A189 6-2 SM

Table of Contents