The following table shows the error codes and their possible causes.
Code No.
Potential sensor
ID sensor
Development unit
Drum unit
Main charge corona unit
High voltage power supply board
LD
Electrical noise
Short waitting time
Humidity and temperature sensor
80
V
SG
_ave Error

∆∆∆

81
V
SG
_ptn Error

∆∆∆

85
Vmin (color) difference
Error

∆∆∆

90
Development potential
calibration error

91
V
D
error at home position

∆∆∆
92
V
G
error



93
12-step pattern error

∆∆
94
Development
γ
calibration error

∆∆∆

95
V
min
error

∆∆

96
V
R
error

∆∆

99
Others
∆∆∆∆∆∆∆∆∆
:
Most probable cause
:
Probable cause
:
Possible cause
: No Relation