(1) Developer Agitation Result
When an error occurs during the developer agitation (SP2-225)
, the
machine stops the sequence and generates/stores the error code in
SP3-964.
The machine also remembers when the error occurred in the sequence.
Therefore, when performing developer agitation (SP2-225-5)
after
recovering the error, developer agitation (SP2-225-5)
starts from a suitable
point in the sequence.
This is the reason why the main switch should not be turned off and on after
an error occurs.
For the developer agitation, steps 1 and 2 must be performed for all colors
completely. This means that when error No. 70 to 72 and 78 is displayed,
you should repair the problem and perform developer agitation (SP2-225-5)
until the error code does not appear.