OfficeServ 7100 PROGRAMMING
TECHNICAL MANUAL PART 2 APRIL 2007
MMC: 747 VM ALARM
DESCRIPTION:
This MMC is only used for the Samsung embedded Voicemail.
This MMC will generate an alarm message in the mailbox defined in MMC 745
whenever the Voicemail disk drive reaches this threshold.
The threshold is measured in % full. This means that if the MMC is set for 80, the
alarm will be generated when the disk exceeds 80% of the available drive space.
The end user should be instructed to delete old messages to recover disk space.
PROGRAM KEYS
UP & DOWN Used to scroll through options
KEYPAD Used to enter selections
SPEAKER Used to store data and advance to next MMC
ACTION DISPLAY
1. Press TRANSFER 747.
Display shows.
VM ALARM
THRESHOLD:80
2. Enter new threshold level.
VM ALARM
THRESHOLD:75
3. Press TRANSFER button to store and exit
OR
Press SPEAKER button to store and
advance to next MMC.
DEFAULT DATA: 80%