OfficeServ 7100 PROGRAMMING
TECHNICAL MANUAL PART 2 APRIL 2007
MMC: 206 BARGE-IN TYPE
DESCRIPTION:
Sets the type of barge-in that is permitted.
OPTION TYPE OF BARGE-IN DESCRIPTION
0 NO BARGE-IN Barge-in feature is unavailable regardless of
a station’s barge-in status.
1 WITH TONE Barge-in will have an intrusion tone and
display at the barged-in on station.
2 WITHOUT TONE Barge-in is allowed. There is no barge-in
tone or display at the barged-in on station
and the barging-in station will be muted.
PROGRAM KEYS
UP & DOWN Used to scroll through options
KEYPAD Used to enter selections
SOFT KEYS Move cursor left and right
SPEAKER Used to store data and advance to next MMC
ACTION DISPLAY
1. Press TRANSFER 206
Display shows
BARGE IN TYPE
NO BARGE IN
2. Dial 0–2 to select barge-in type (e.g., 2)
OR
BARGE IN TYPE
WITHOUT TONE
Press UP or DOWN to select barge-in type
and press RIGHT soft key.
3. Press TRANSFER to store and exit
OR
Press SPEAKER to store and advance to next
MMC.
DEFAULT DATA: NO BARGE-IN
RELATED ITEMS: MMC 301 ASSIGN STATION COS
MMC 701 ASSIGN COS CONTENTS