Index-4 GWA 4NEB 631 6050-22 DS 03
Index
Decoupling module pin assignment
13-24
Degree of protection (according to
IEC 60529) D-2
Delay xii, 3-12
Delay time 1-100, 7-11
Delay time for sensor inputs
50ms/10ms 10-20
Delta networks 1-98
Device class 1-91
Device data 12-2
Device data (GSD file) Glossary-5
Device family 1-90
Device I/Os 1-52
Device I/Os (OPD) 1-46
Device parameters 12-1
Device replacement 1-107
Device series 1-7
Device subfamily 1-90
Device test active 1-65
Diagnostic alarms 12-7
Diagnostic data 1-5, 1-23
Diagnostic device fault 1-74
Diagnostic message "Local" and
"PROFIsafe" 1-23
Diagnostic warning 1-74
Diagnostics data 12-7
Diagnostics for device faults 12-7
Diagnostics for process events 12-7
Diagnostics for process warnings 12-7
Digital module 1-77, 1-100, 13-2, 14-2, F-3,
F-9, Glossary-5
Digital module 1 as DM-F Local 1-78
Digital module 1 inputs 7-3
Digital module 1 is DM-F PROFIsafe 1-78
Digital module 2 inputs 7-3
Digital module connection example 13-17
Digital module DM-F Local 1-102, 13-2,
14-2, F-3, F-9
Digital module DM-F Local connection
example 13-28
Digital module DM-F Local pin
assignment 13-26
Digital module DM-F PROFIsafe 1-102,
13-2, 14-2, F-3, F-9
Digital module DM-F PROFIsafe connec-
tion examples 13-29
Digital module inputs 7-9
Digital module outputs 6-9
Digital module pin assignment 13-16
Digital modules 1-25, 1-99
Digital modules DM-F Local and
DM-F PROFIsafe 13-5, 13-25, C-15,
Glossary-5
Dimension drawings C-1
DIP positions, enabling circuit 0>1, digital
module DM-F Local 1-88
DIP switch
Glossary-5
DIP switc
h, DM-F Local D-16
DIP switch, DM-F PROFIsafe D-17
DIP switches, DM-F PROFIsafe 10-2
2
DIP switches, DM-F Local 1-66, 10-19,
10-20
Direct starter 1-9, 1-10, 1-13, 1-19, 1-30,
4-14, 4-23, B-46, E-6, E-7
Direct starter for 1-phase loads E-50,
E-51
Direct starter control function 4-22
Direction of rotation 4-24
Display 1-92
Display of all pending faults 1-86
Display of all pending status
information 1-86
Display of all pending warnings 1-86
Display of measured values in the measu-
red values display 1-60
Display of statistical and maintenance-rele-
vant information on the statistics/main-
tenance display 1-67
Display settings 1-52
Display settings (OPD) 1-47
Display, operator panel with display D-23
Displays (lamp control) 4-12
Displays of the operator panel with
display 1-38, 1-51
Displays the current status of all
device I/Os 1-75
DM Inputs 7-11
DM Outputs 6-9
DM1(2) Inputs 1-118
DM1(2) Inputs, DM-F = DM-F Local or DM-
F PROFIsafe 1-118
DM1(2) Outputs 1-118
DM-F Abbreviations-1
DM-F - Test requirement 15-2
DM-F DIP switch
1-101
DM-F feedback circuit 15-2
DM-F Local 1-18
DM-F PROFIsafe 1-18
DM-F PROFIsafe, inputs 1,2,3, feedback
circuit 1-78
DM-F safety-oriented tripping 15-2
DM-F system interfaces 1-101
DM-F wiring 15-2
DM-FL - Configuration deviation 15-2
DM-FL - Configuration mode 15-3
DM-FL - Cross circuit 15-3
DM-FL - Simultaneity 15-3
DM-FL waiting for start-up test 15-3
DM-FP F PRM error 15-3
DM Inputs function blocks 7-9

Table of Contents

Other manuals for Siemens SIMOCODE pro

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Siemens SIMOCODE pro and is the answer not in the manual?

Siemens SIMOCODE pro Specifications

General IconGeneral
Protection ClassIP20
Mounting TypeDIN rail mounting
Rated Operational Voltage24 V DC
Rated CurrentUp to 820 A
Protection FunctionsOverload, short-circuit, phase failure, asymmetry, ground fault, motor stall
Operating Temperature Range-25°C to +60°C
Communication ProtocolsPROFIBUS DP, PROFINET, Modbus RTU
Analog OutputsUp to 2
Temperature MonitoringPTC/KTY, RTD (PT100/PT1000)
Digital OutputsRelay outputs, Solid-state outputs
Analog Inputs0/4-20mA, PT100/PT1000