5.26 Variable S_NCCODEREADONLY
Description
The screen property S_NCCODEREADONLY is only relevant when a cycle is recompiled in
the editor with a "Run MyScreens" dialog. S_NCCODEREADONLY determines whether a
recompiled NC code from the editor can be changed or not.
The following applies for the return value:
TRUE: The recompiled NC code from the editor can be changed
FALSE: The recompiled NC code from the editor cannot be changed (read-only), because,
for example, it is already in the preprocessing (= TRUE).
5.27 Variables S_RESX and S_RESY
Description
The current resolution or its X and Y component can be queried in the configuration with the
screen properties S_RESX and S_RESY.
Example
REG[0] = S_RESY
See also
RESOLUTION (Page 105)
Variables
5.27 Variables S_RESX and S_RESY
SINUMERIK Integrate Run MyScreens
Programming Manual, 10/2015, 6FC5397-3DP40-5BA3 89