9 = 0 ; Feed enable missing
10 = 0 ; Dwell time active
12 = 0 ; Axis enable missing
16 = 0 ; Waiting for other channel
17 = 0 ; Waiting for feedrate override
18 = 0 ; Error in NC block
19 = 0 ; Waiting for external NC blocks
22 = 0 ; Spindle enable missing
23 = 0 ; Axis feedrate override
32 = 0 ; Oscillation active
45 = 0 ; Search target found
76 = 0 ; Wait: G64 still U
5.5 Deactivating program test
There are several program test options to test and run-in a part program that are executed
using the "Program Test" function.
This
function is active
as standard. You can select the program test in the "Machine" operating
area, in the "Program control" window and using the "PRT" check box.
Deactivating the program test
You can deactivate the program test using the following configuration machine data. "PRT" is
no longer displayed in the status line.
MD51039 $MNS_PROGRAM_CONTROL_MODE_MASK Options for machine - program
control
Bit 0 = 0 Function program test not available
The test option is described in the following documentation:
References
Function Manual, Basic Functions,
Mode Group, Channel, Program Operation, Reset Behavior
(K1)
5.6 Activating the "Teach In" function
Activate TEACH IN
The TEACH IN function is activated in part via the general configuration machine data.
Customizing the "Machine" operating area
5.6 Activating the "Teach In" function
SINUMERIK Operate
Commissioning Manual, 10/2015, 6FC5397-3DP40-5BA3 55