10.3 This is how you back up just the machine data that have changed
Requirement
The access level "Service" is required.
Delta backup only for machine data that has changed
Using
the
general
MD11210
$MN_UPLOAD_MD_CHANGES_ONLY, you can set whether all
machine data should be backed up in the archive, or only the machine data that differs from
the default setting:
MD11210 $MN_UPLOAD_MD_CHANGES_ONLY
Backing up just machine data that has changed
= FFH (default setting)
Bit 0
...
Bit 7
Note
Effect on commissioning archives
MD11210 $MN_UPLOAD_MD_CHANGES_ONLY is only effective for type *.arc archives.
Generating an archive
Procedure:
1. Insert the storage medium
(CompactFlash card or USB FlashDrive) in the appropriate slot
at the front of the control.
2. To generate a type *.arc archive press the keys <Ctrl> + <Alt> + C.
Result:
An archive is generated on the storage medium:
The archive name has the following structure: CompleteArchive_Date_Time.arc
Example:
CompleteArchive2010-08-11_08-36-15.arc stands for an archive generated on 11.08.2010 at
8:36:15.
Easy Archive
10.3 This is how you back up just the machine data that have changed
CNC commissioning
Commissioning Manual, 10/2015, 6FC5397-3DP40-5BA3 337