10.5 This is how you import a commissioning archive
Precondition
The access level "User" is necessary for reading in an archive.
Reading-in a commissioning archive
Procedure:
1.
Select the "Startup" operating area.
2.
Press the menu forward key and then the "Startup archive" softkey.
The "Startup" window is opened.
3.
Select the "Read in startup archive" option and confirm with "OK".
The "Select startup archive" window is opened.
4. Select the archive and confirm with "OK".
5. To read in the archive, acknowledge the confirmation prompt with "OK".
The "Read In Archive" window opens and a progress message box appears for the read-
in process.
6. Press the "Cancel" softkey to cancel the read-in process.
Easy Archive
10.5 This is how you import a commissioning archive
CNC commissioning
340 Commissioning Manual, 10/2015, 6FC5397-3DP40-5BA3