Pin Signal name NC variable Meaning
13 O12 DOUT12 --
Without analog spindle:
Digital NC output 12
With analog spindle:
Travel direction of the analog spindle (in
accordance with
MD30134 $MA_IS_UNIPOLAR_OUTPUT)
14 M3 MEXT3
Ground for pins 9, 10, 12, 13
NOTICE
Shielded signal cables for analog signals
To ensure safe, fault-free operation of the system, shielded cables with shield connection
should be used for the wiring of the analog outputs.
(See also: EMC compatibility)
See also
Machine data for an analog spindle (Page 85)
Commissioning the drive
5.5 Terminal assignments
CNC commissioning
148 Commissioning Manual, 10/2015, 6FC5397-3DP40-5BA3

Table of Contents