File overview
The following files are required:
Name Path Meaning
versions.xml /siemens/sinumerik/hmi/data/version/oem/cma Version file
versions.xml /oem/ Version path file
Adapting the version file
The cycles version specification requires a manual adaptation of the version file.
1. Copy the "versions.xml" sample file from the following directory:
/siemens/sinumerik/hmi/data/version/oem/cma
2. Save the sample file in its own directory under /oem.
The standard directory for this purpose is /oem/sinumerik/hmi/data/version/oem/cma.
3.
Open the file.
4. Enter the planned version for the cycles files in the <info> tag with "defaultFileVersion" and
the details for the complete version in the <Version> tag.
5. Close the file to save the changes.
Example:
<info defaultFileType=" *.spf *.cpf" defaultFileVersion="05.05.00.00"
linkname="CMA" linkpath="//NC/CMA.DIR" EffDirOrder="CUS CMA">
<Name>Manufacturer cycles</Name>
<Version>5.5.0.0</Version>
<Link>
<Name>CUS</Name>
<Path>//NC/CUS.DIR</Path>
</Link>
</info>
Adapting the version path file
If
the version file
is saved in the standard directory, and a current oem\versions.xml is available,
no changes are required. In all other cases, the path data can be manually changed:
1. Open the versions.xml file under /oem
2. Replace the standard path in the <Path> tag for the "Manufacturers Cycles" with your own
path for the version file.
3. Close the file to save the changes.
Standard:
<Component>
<Name>Manufacturer Cycles</Name>
<Path>/siemens/sinumerik/hmi/data/version/oem/cma</Path>