Description
Identifier <tag> Meaning
AGM Identifier for the "Startup Wizard"
DEVICE
Identifier for the description of the device.
Attributes:
● option_bit
The device is assigned a fixed bit number for the option
management.
NAME The identifier specifies the name of the device to be displayed in the
dialog.
If
a text
reference is used, the dialog displays the text which is saved
for the identifier.
START_UP The identifier contains a description of the sequences required for
commissioning the device.
SET_ACTIVE The identifier contains a description of the sequences required to
activate the device.
Attributes:
● timeout
The attribute permits a timeout to be specified in seconds. The
system interrupts processing if the script has still not been
completed after this time.
SET_INACTIVE The identifier contains a description of the sequences required to shut
down the device.
Attributes:
● timeout
The
attribute permits
a timeout to be specified in seconds. The system
interrupts processing if the script has still not been completed after
this time.
TEST The identifier contains the statements for testing the operating capa‐
bility of a device.
Attributes:
● timeout
The attribute permits
a timeout to be specified in seconds. The system
interrupts processing if the script has still not been completed after
this time.
UID Unique numerical identifier to identify the device in the PLC ↔ HMI
interface.
VERSION Identifier for a version
Negative acknowledgment of the function execution
With the automatically
provided variable "$actionresult", the system can inform the XML parser
of a negative execution result. If the value is set to zero, the parser aborts the function
processing.
Generating commissioning dialogs
2.6 Script language
Easy XML
130 Programming Manual, 10/2015, 6FC5397-3DP40-5BA3