Executing the OPC UA configuration dialog
Start the OPC UA configuration dialog via the operating area "Startup > Network".
Figure 2-2 OPC UA configuration dialog (initial state)
Press the "Change" button.
Table 2-1 Settings of the OPC UA configuration dialog
Setting Description
IP address The IPv4 address of the target system. This is determined automatically.
Check these:
for the NCU and PPU -X130
for the PCU 50 Local Area Connection 2
Port TCP port, communicates via the OPC UA. This is added to the firewall
exceptions for NCU and PPU.
(The standard for the OPC UA communication is the TCP port 4840)
Admin User Name of the administrator; with it you can add or delete other users and
assign or delete user authorizations.
Password Password of the administrator.
Activate OPC UA Place the checkmark to activate OPC UA and remove the checkmark to
deactivate it.
Setting up OPC UA components
2.2 Setup
SINUMERIK Integrate for Engineering Access MyMachine / OPC UA
Commissioning Manual, 10/2015, 6FC5397-3DP40-5BA3 9

Table of Contents

Other manuals for Siemens SINUMERIK 828D

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Siemens SINUMERIK 828D and is the answer not in the manual?

Siemens SINUMERIK 828D Specifications

General IconGeneral
Control TypeCNC
Operating SystemWindows Embedded
ProcessorIntel Atom
Display10.4" color TFT display
InterfacesEthernet, USB
ProgrammingShopMill, ShopTurn
Operation Panel Size10.4"
Protection ClassIP65
PLC Memory2 MB
Spindle Capacity4 spindles
Hard DriveCompactFlash

Related product manuals