EasyManuals Logo

Siemens SINUMERIK 828D Commissioning Manual

Siemens SINUMERIK 828D
1167 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #903 background imageLoading...
Page #903 background image
Figure 2-4 Security message for opening the TCP port
Checking the HMI time
You must correctly set the HMI time so that the secure OPC UA communication functions.
Note
The certificate
needed for secure OPC UA communication (../siemens/sinumerik/hmi/miniweb/
System/Cert/servercerts/MiniWeb_OPCUA.crt) is automatically created during the first run-up.
The start date of the validity period is set to the current date. The validity period is 30 years.
If the time is subsequently changed so that it lies outside the validity period, the secure OPC
UA communication does not function (BadCertificateTimeInvalid).
Performing a restart
Perform a hardware restart on the target systems NCU and PPU. A restart of the
SINUMERIK Operate is necessary on the PCU 50.
Setting up OPC UA components
2.2 Setup
SINUMERIK Integrate for Engineering Access MyMachine / OPC UA
Commissioning Manual, 10/2015, 6FC5397-3DP40-5BA3 11

Table of Contents

Other manuals for Siemens SINUMERIK 828D

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Siemens SINUMERIK 828D and is the answer not in the manual?

Siemens SINUMERIK 828D Specifications

General IconGeneral
Control TypeCNC
Operating SystemWindows Embedded
ProcessorIntel Atom
Display10.4" color TFT display
InterfacesEthernet, USB
ProgrammingShopMill, ShopTurn
Operation Panel Size10.4"
Protection ClassIP65
PLC Memory2 MB
Spindle Capacity4 spindles
Hard DriveCompactFlash

Related product manuals