Chapter 4 — Configuring the Library Configuring Optional Library Settings
November 2016 User Guide—Spectra T950 Library
138
Usethefollowingstepstodetermineifthebarcodelabelsonyour
cartridgesincludeachecksumcharacter.
1. Logintothelibraryasauserwithsuperuseroradministrator
privileges.
2. Fromthetoolbarmenu,select Maintenance > Tools.TheMaintenance
Toolsscreendisplays.
3. SelectUtilities.TheUtilitiesscreendisplays.
4. ClickShow Advanced.TheAdvancedUtilitiesConfirmationscreen
displays.
5. ClickNext.TheUtilitiesscreenrefreshestoshowalistoftheadv anced
utilities.
6. SelecttheModify Barcode Reporting utility.Thescreenrefreshestoshow
thedetailsfortheutility.
7. Makesurethattheoptionsfortheutilityaresetasfollows:
8. Examineeachbarcodelabelyouwanttotestandmakeanoteofthe
human‐readabletextoneach.
9. Importthecartridgesintoastoragepartition,thenviewthepartition
inventory,eitherontheBlueScaleInventoryscreen(see
Viewthe
CartridgeInventoryforaLocationonpage258)orthroughyour
storagemanagementsoftware.
Ifthereportedbarcodeexactlymatchesthehuman‐readabletext
yourecorded,thenthebarcodeincludesachecksumcharacter.
Ifthereportedbarcodeismissingtheright‐mostcharacter,thenthe
barcodedoesnotincludeachecksumcharacter.
10. SeeChangingtheLibrary’sDefaultBarcodeReportingConfiguration
onpage135toconfigurethebarcodereportingtomatchyourbarcodes.
After the utility completes, the LCM reboots. After the library completes its
initialization, it rescans the barcode labels of all media in the library. This rescan
takes up to 45 minutes per frame to complete.
For this field... Make sure it is set to...
Select checksummed behavior Ignorecheck‐sumbarcodes
Select Right or Left Reportright‐handcharacters
Select the number of characters to
report: (1 - 16)
16