Chapter 12 — Library Troubleshooting Restoring the Library Configuration
November 2016 User Guide—Spectra T950 Library
387
7. ScrollthroughthelistofadvancedutilitiesandselectRestore Library
Configuration from Auto Save.Thescreenrefreshestoshowthedetails
fortheutility.
8. UsetheSelect a configuration time stampdrop‐downlisttoselectthe
configurationbackupfileyouwanttouse.Theautomaticallygenerated
configurationbackupfilesarenamed<date-time>cfg.zip,where
<date-time>isthetimestampforwhenthefilewascreated.
UnlessyoureplacetheLCMoritsmemorycard,thefirstfilelistedis
thezippedconfigurationbackupfilestoredontheLCMmemorycard.
Note: Ifav ailable,thezippedconfigurationbackupfilestoredontheLCM
memorycardusuallycontainsthemost recentlysav edlibrary
configurationinformation,aswellastheMLMandDLMdatabases.
Checkthetimestampinthefilenametodeterminewhetherany
manuallygeneratedbackupfileyouhav eismorerecent.
9. ClickRun Utility.
Afterabriefdelay,theUtilityResultsscreenappears,showingthatthe
configurationwasrestored.Thelibrarythenperformsapower‐cycle
reset.
Figure 251 The Restore Library Configuration from Auto
Save utility.
Before the library is restored using the configuration backup file on a USB device,
the library’s current configuration is saved to the USB device with a time stamp
indicating when the file was created. The library is then restored using the selected
configuration backup file on the USB device.
The USB device now contains one additional Auto Configuration Save file.