6-31
IM 701450-01E
6
Triggers
Setting the Level, Hysteresis, Trigger Coupling, and HF Rejection
7. Press the Level/Coupling soft key. The Level/Coupling dialog box opens.
8. Like in the case of the A->B(N) trigger, set the level, hysteresis, trigger coupling,
and HF rejection.
• The setup procedure is common to the A->B(N) trigger. See page 6-16.
• If Window is ON, set the window position and width, trigger coupling, and HF rejection.
The setting is the same as the window trigger. See section 6.13.
9. Press ESC. The Level/Coupling dialog box closes.
Note
The trigger level, hysteresis, trigger coupling, and HF rejection settings apply to both simple
and enhanced triggers.
Setting the Window
10. Press the Window soft key to select ON or OFF.
• If set to OFF, a trigger is activated on the OR logic of the edge of each channel.
• If set to ON, a trigger is activated on the OR logic of the window condition of each
channel.
Setting the Hold Off
11. Set the hold off time according to the procedures given in section 6.4.
6.12 Setting the OR Trigger (ENHANCED)