544
S:\Hp8960\E1962B CDMA 2000\Pi Release\Reference Guide\Chapters\cdma2000_hpib_setup_fm.fm
SETup:FM
SETup:FM:FILTer[:TYPE]
SETup:FM:FILTer:TBPass[:FREQuency]
SETup:FM:FREQuency:STATe
Function Sets/queries the filter type for FM measurements.
Setting Range: NONE|TBPass|CMESsage|BPASs50|BPASs300
Query Range: NONE|TBP|CMES|BPAS50|BPAS300
*RST setting NONE
Programming Example
10 OUTPUT 714;SETUP:FM:FILTER:TYPE BPAS50
!Selects the 50 Hz to 15 kHz bandpass filter.
Function Sets/queries the center frequency for the 100 Hz tunable bandpass filter (TBPass).
Setting Range: 300.0 to 15000 Hz
Resolution: 0.1 Hz
Query Range: 300.0 to 15000 Hz
*RST setting 1004 Hz
Programming Example
10 OUTPUT 714;SETUP:FM:FILTER:TBPASS:FREQUENCY 300HZ
Function Sets/queries whether the FM modulation frequency measurement is enabled.
Setting Range: 1|ON|0|OFF
Query Range: 1|0
*RST setting 0 (off)
Programming Example
OUTPUT 714;SETUP:FM:FREQUENCY:STATE ON