544
S:\Hp8960\E1962B CDMA 2000\Pi Release\Reference Guide\Chapters\cdma2000_hpib_setup_fm.fm
SETup:FM
SETup:FM:FILTer[:TYPE]
SETup:FM:FILTer:TBPass[:FREQuency]
SETup:FM:FREQuency:STATe
Function Sets/queries the filter type for FM measurements.
Setting Range: NONE|TBPass|CMESsage|BPASs50|BPASs300
Query Range: NONE|TBP|CMES|BPAS50|BPAS300
*RST setting NONE
Programming Example
10 OUTPUT 714;SETUP:FM:FILTER:TYPE BPAS50
!Selects the 50 Hz to 15 kHz bandpass filter.
Function Sets/queries the center frequency for the 100 Hz tunable bandpass filter (TBPass).
Setting Range: 300.0 to 15000 Hz
Resolution: 0.1 Hz
Query Range: 300.0 to 15000 Hz
*RST setting 1004 Hz
Programming Example
10 OUTPUT 714;SETUP:FM:FILTER:TBPASS:FREQUENCY 300HZ
Function Sets/queries whether the FM modulation frequency measurement is enabled.
Setting Range: 1|ON|0|OFF
Query Range: 1|0
*RST setting 0 (off)
Programming Example
OUTPUT 714;SETUP:FM:FREQUENCY:STATE ON

Table of Contents

Other manuals for Agilent Technologies 8960 Series

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Agilent Technologies 8960 Series and is the answer not in the manual?

Agilent Technologies 8960 Series Specifications

General IconGeneral
BrandAgilent Technologies
Model8960 Series
CategoryTest Equipment
LanguageEnglish

Related product manuals